Solar Inverter & Power Conditioning Unit

GKE SOALR UPS is an integrated system consisting of a solar charge controller. Inverter and an AC mains charger. Batteries are charged either through Solar /Grid/DG set or with sharing of current. System gives priority to Solar Power first and uses Grid power only when Solar power/ Battery charge is insufficient to meet the load requirements. Battery Voltage, Solar power output and the load are continuously monitored. When Batteries are charged to preset l

Solar Higher Range PWM & MPPT Inverter PCU

Product Image
  • Water Filtration Plant
  • Water Filtration Plant
  • Water Filtration Plant
  • Water Filtration Plant
  • Water Filtration Plant
Get Best Quote
Approx. Price: Rs 15,000 / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity10 Piece
Grid TypeOff Grid
BrandGKE
Output Frequency50 Hz
Degree Of ProtectionIP 65
Warranty2 Year
Power Factor0.8
CertificationCE
DisplayLCD
Ac Over Voltage / Current Limitation ProtectionYes
Input-Side Disconnection DeviceYes

GKE SOALR UPS is an integrated system consisting of a solar charge controller. Inverter and an AC mains charger.

Technical Specification

 

 

 

 

VA Rating

2.5 KVA

3.5 KVA

5 KVA

6 KVA

7.5 KVA

10 KVA

Battery Voltage

36V DC/ 48V DC

48V DC

48V DC/ 96V DC

120V DC

120V DC

180V DC/ 192V DC

Solar Panel Connected

for 40/60 Amps

PWM/MPPT* Charge Controller (Max.)

 

2000W/ 3000W

2000W/

3000W

3000W/

5000W

6000W/

7200W

6000W/

7200W

8000W/

10000W

 

AC Mains Mode

Input Voltage Range (Normal Mode)

100 to 280 VAC ± 5 VAC (Wide Range)

Input Voltage Range (UPS Mode)

180 to 260 VAC ± VAC

Changeover Time Maximum

< 30 ms (in Normal Mode) and < 10 ms (in UPS Mode)

Max. Charging Current (LC)

12A + 1A

Max. Charging Current (HC)

14A + 1A

Boost Charging Voltage

14.5 ± 0.2 VDC

29 V ±0.4 VDC

Float Charging Voltage

13.8 ± 0.2 VDC

27.6 ± 0.4 VDC

Battery Backup Mode

Output Voltage at No Load

220 VAC ± 7 VAC

Output Frequency

50.0Hz ± 0.5Hz

Output Wave Form (At No Load)

100% Pure Sine Wave

Battery Low alarm

10.5± 0.2 VDC

21.0 ± 0.2 VDC

Battery Low protection

10.2 ± 0.2 VDC

20.4 ± 0.2 VDC

Overload (Normal/ UPS)

120%

Short Circuit (Normal/ UPS)

300%

Charging Mode - SOLAR (MPPT Charge Controller/PWM)

Max. Charging Current (HC)

40 Amp./60A ± 1.5Amp.

 

Request
Callback
Yes! I am interested

Solar Inverter & Power Conditioning Unit

Product Image
  • Water Filtration Plant
  • Water Filtration Plant
  • Water Filtration Plant
  • Water Filtration Plant
  • Water Filtration Plant
  • Water Filtration Plant
Get Best Quote
Approx. Price: Rs 2,500 / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity10 Piece
BrandGKE
Grid TypeOff Grid
Output Frequency50 Hz
Power Factor0.8
TopologyTransformered
MNRE ApprovedNo
Ac Over Voltage / Current Limitation ProtectionYes
Input-Side Disconnection DeviceYes
Over Voltage / Current Limitation ProtectionYes
DC Reverse Polarity ProtectionYes

GKE SOALR UPS is an integrated system consisting of a solar charge controller. Inverter and an AC mains charger.

Technical Specification

Model

700 VA H-UPS

900 VA H-UPS

1100 VA H-UPS

1600 VA H-UPS

2000 VA H-UPS

Nominal Battery Voltage

12 VDC

24 VDC

Solar Panel Connected for 40/60 Amps PWM/MPPT* Charge Controller (Max.)

850Wp

850Wp

850Wp

1700Wp

1700Wp

AC Mains Mode

Input Voltage Range (Normal Mode)

100 to 280 VAC ± 5 VAC (Wide Range)

Input Voltage Range (UPS Mode)

180 to 260 VAC ± VAC

Changeover Time Maximum

< 30 ms (in Normal Mode) and < 10 ms (in UPS Mode)

Max. Charging Current (LC)

12A + 1A

Max. Charging Current (HC)

14A + 1A

Boost Charging Voltage

14.5 ± 0.2 VDC

29 V ±0.4 VDC

Float Charging Voltage

13.8 ± 0.2 VDC

27.6 ± 0.4 VDC

Battery Backup Mode

Output Voltage at No Load

220 VAC ± 7 VAC

Output Frequency

50.0Hz ± 0.5Hz

Output Wave Form (At No Load)

100% Pure Sine Wave

Battery Low alarm

10.5± 0.2 VDC

21.0 ± 0.2 VDC

Battery Low protection

10.2 ± 0.2 VDC

20.4 ± 0.2 VDC

Overload (Normal/ UPS)

120%

Short Circuit (Normal/ UPS)

300%

Charging Mode - SOLAR (MPPT Charge Controller – 40/60 Amp.)

Max. Charging Current (HC)

40/60Amp. ± 1.5Amp.

Charge Controller Efficiency

> 95%

 